Part Number Hot Search : 
A5358CA HA2520 500000 PSMN0 2N6292 PTN3360 BL1102 1N6711B
Product Description
Full Text Search
 

To Download 2001 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 2001 2002
712-Digit High Performance Multimeter 812-Digit High Performance Multimeter
DMM users whose applications demand exceptional resolution, accuracy, and sensitivity combined with high throughput now have two attractive alternatives to high priced, high-end DMMs. Keithley's 712-digit Model 2001 and 812digit Model 2002 High Performance Digital Multimeters not only deliver performance specifications usually associated only with instruments that cost thousands more, but they also offer a broad range of functions not typically available from DMMs.
High Throughput, High Accuracy DCV and Resistance Measurements In applications where high throughput is critical, both the 2001 and 2002 provide more than 2000 readings per second at 412-digit resolution. At 712 digits, the 2002 maintains full rated accuracy at reading rates up to 44/second on DCV and ohms. The Model 2002 uses a unique single-phase method for 4-wire ohms measurements. This makes it twice as fast for a given power line cycle rate. This also eliminates errors due to changing lead resistances that can result from fast test handlers. A built-in "open-lead" detection circuit also eliminates many production test problems.
* True 712- (Model 2001) or 812digit (Model 2002) resolution * Exceptional measurement integrity with high speed * Broad range of built-in measurement functions * Built-in 10 channel scanner option * IEEE-488.2 and SCPI compatible * Model 2002 has HP 3458A emulation mode
High Accuracy ACV Measurements A patented circuit design makes the 2001 and 2002's AC measurements several times more accurate than competitive DMMs, thus maintaining very good accuracy (better than 0.1%) down to 1Hz. The wide bandwidth of these DMMs allows for accurate measurements of high frequency AC signals without the need for a special AC meter. Both the 2001 and 2002 feature TRMS AC, Average AC, Peak AC, AC+DC, and Crest Factor measurement capability for a wide variety of applications.
ACCESSORIES AVAILABLE
TEST LEADS AND PROBES
5805 8606 7007-1 7001-2 7009-5 4288-1 4288-4 Kelvin Probes, 0.9m (3 ft) High Performance Modular Probe Kit Shielded GPIB Cable, 1m (3.3 ft) Shielded GPIB Cable, 2m (6.6 ft) RS-232 Cable Single Fixed Rack Mount Kit Side by Side Rack Mount Kit
CABLES/ADAPTERS
RACK MOUNT KITS
1.888.KEITHLEY
(U.S. only)
www.keithley.com
A GREATER MEASURE OF CONFIDENCE
D I G I T A L M U LT I M E T E R S
Built-In Scanner (Multiplexer) OTHER Options KPCI-488 IEEE-488 Interface/Controller for the PCI Bus KPC-488.2AT IEEE-488 Interface Card for IBM PC/AT (full slot) With the addition of a plug-in scanner card, it becomes a complete scan and measure system for applications involving up to ten measurement points. The additional resolution and measurement ranges provided by the 2002 make it an excellent choice for production test, design verification, and metrology applications where high accuracy is critical.
High resolution, high accuracy DMMs
True 712- (or 812-) Digit Resolution While other DMMs may claim 712- or 812-digit resolution, those instruments must average multiple readings to extend their resolution. The resolution specifications of the 2001 and 2002 are based on a 28-bit A/D converter that provides the resolution needed to discern smaller changes. This higher resolution also provides greater dynamic range, making it possible to measure from 1V to 20V on a single range, thus avoiding range-shift errors and delays.
2001 2002
Ordering Information
2001 High Performance 712-Digit DMM with 8K Memory 2001/MEM1 High Performance 712-Digit DMM with 32K Memory 2001/MEM2 High Performance 712-Digit DMM with 128K Memory 2002 High Performance 812-Digit DMM with 8K Memory 2002/MEM1 High Performance 812-Digit DMM with 32K Memory 2002/MEM2 High Performance 812-Digit DMM with 128K Memory 2000-SCAN 10-Channel Scanner Card 2001-SCAN 10-Channel Scanner Card with two high-speed channels 2001-TCSCAN 9-Channel Thermocouple Scanner Card These products are available with an Extended Warranty. Accessories Supplied Model 8605 High Performance Modular Test Leads, user's manual, option slot cover, and full calibration data.
712-Digit High Performance Multimeter 812-Digit High Performance Multimeter
2001 Condensed Specifications
DC VOLTS
RANGE 200 mV 2V 20 V 200 V 1000 V ACCURACY (ppm of reading INPUT + ppm of range) RESOLUTION RESISTANCE 90 Days 10 nV >10 G 25 + 6 100 nV >10 G 18 + 2 1 V >10 G 18 + 4 10 V 10 M 1% 27 + 3 100 V 10 M 1% 31 + 6 ACCURACY (ppm of reading CURRENT + ppm of range) SOURCE 90 Days 9.2 mA 52 + 7 0.98 mA 36 + 7 0.98 mA 33 + 4 89 A 32 + 4 7 A 72 + 4.5 770 nA 110 + 4.5 70 nA 560 + 4.5 4.4 nA 10000 + 100 4.4 nA 20000 + 100 ACCURACY MAXIMUM (ppm of reading BURDEN + ppm of range) VOLTAGE 90 Days 0.25 V 300 + 25 0.31 V 300 + 20 0.4 V 300 + 20 0.5 V 300 + 20 1.5 V 600 + 20
2002 Condensed Specifications
DC VOLTS
RANGE 200 mV 2V 20 V 200 V 1000 V ACCURACY (ppm of reading INPUT + ppm of range) RESOLUTION RESISTANCE 90 Days 1 nV >100 G 15 + 8 10 nV >100 G 6 + 0.8 100 nV >100 G 6 + 0.15 1 V 10 M 1% 14 + 2 10 V 10 M 1% 14 + 0.4 ACCURACY (ppm of reading CURRENT + ppm of range) SOURCE 90 Days 7.2 mA 15 + 6 960 A 15 + 4 960 A 7 + 0.4 96 A 7 + 0.4 9.6 A 29 + 0.8 1.9 A 53 + 0.5 1.4 A 175 + 0.6 1.4 A 500 + 3 1.4 A 2000 + 15 ACCURACY MAXIMUM (ppm of reading BURDEN + ppm of range) VOLTAGE 90 Days 0.25 V 275 + 25 0.3 V 275 + 20 0.35 V 275 + 20 0.35 V 300 + 20 1.1 V 600 + 20
Model 2001 and 2002 Specifications
RESISTANCE
RANGE 20 200 2 k 20 k 200 k 2M 20M 200M 1G RESOLUTION 1 10 100 1m 10m 100m 1 10 100
RESISTANCE
RANGE 20 200 2 k 20 k 200 k 2M 20M 200M 1G RESOLUTION 100 n 1 10 100 1m 10m 100m 1 10
DC AMPS
RANGE 200 A 2 mA 20 mA 200 mA 2A RESOLUTION 10 pA 100 pA 1 nA 10 nA 100 nA
DC AMPS
RANGE 200 A 2 mA 20 mA 200 mA 2A RESOLUTION 10 pA 100 pA 1 nA 10 nA 100 nA
GENERAL/STANDARDS COMPLIANCE
POWER Voltage: 90-134V and 180-264V universal self-selecting. , Frequency: 50Hz, 60Hz, or 400Hz self-identifying. Consumption: <55 VA. ENVIRONMENT Operating Temperature: 0 to 50C. Storage Temperature: -40 to +70C. Humidity: 80% R.H., 0 to 35C. Altitude: 4,500m (15,000 ft) operating; 12,000m (40,000 ft.) non-operating. PHYSICAL Case Dimensions: 90mm high x 214mm wide x 369mm deep (312 in x 812 in x 1412 in). Unit Weight: 4.2kg (9.2 lbs). STANDARDS EMI/RFI: Conforms to VDE 0871B (per Vfg 1046/1984), IEC 801-2, FCC part 15 Class B, CISPR-22 (EN55022). Safety: Conforms to IEC348, CAN/CSC22.2 No. 231, MIL-T-28800E1.
FREQUENCY COUNTER
RANGE: 1Hz-15MHz. ACCURACY: (0.03% of reading).
DC IN-CIRCUIT CURRENT
RANGE: 100A to 12A. ACCURACY: (5% + 2 counts) over 2 years. TRACE RESISTANCE: 1m to 10 typical.
D I G I T A L M U LT I M E T E R S
TEMPERATURE
Built-in linearization for J, K, N, T, E, R, S, B thermocouple types to ITS-90 and 100 platinum RTDs. For complete specifications, refer to the 2001 or 2002 Technical Data Book.
For more information, request the Model 2001 and 2002 Technical Specifications books.
1.888.KEITHLEY
(U.S. only)
www.keithley.com
A
GREATER
MEASURE
OF
CONFIDENCE


▲Up To Search▲   

 
Price & Availability of 2001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X